ElectroMAX - Alternative products

HEATRAE SADIA ELECTROMAX - Installation Details



Cold Water Control:
Integrated cold water control set comprising pressure reducing
valve and strainer (factory set at 3.5 bar), expansion relief valve (factory set at 6 bar) and check valve. 22mm compression fittings.

Electrical:
Electrical Designed for connection to off-peak electricity supply. A range of off-peak tariffs are available nationally – it is recommended that you contact your electricity supplier to determine the tariff best suited to your needs.
Electric boiler must be permanently connected to electricity supply through a double pole linked isolating switch with a minimum breaking capacity of 45 Amps.
Immersion heaters must be permanently connected to electricity supply though a double pole linked isolating switch with a minimum breaking capacity of 13 Amps.
Central heating control is by means of a programmable room stat (supplied loose for fitting on site).

Fixing:
Floor mounting. A template is provided to assist in positioning.

Guarantee:
The Electromax Duplex stainless steel vessel carries a full 10-year
guarantee against faulty manufacture or materials provided that:
• It has been correctly installed as per the instructions contained in the
instruction manual and all relevant Codes of Practice and Regulations
in force at the time of installation.
• It has not been modified in any way, other than by Heatrae Sadia Heating.
• It has not been frost damaged.
• It has only been used for the storage of potable water.
• It has not been tampered with or been subjected to misuse or neglect.
• Within 60 days of installation the user completes and returns the certificate supplied along with the proof of purchase to register the product.
The boiler, immersion heater and controls are guaranteed for a period of
2 years from the date of purchase provided that:
• It has been correctly installed as per the instructions contained in the
instruction manual and all relevant Codes of Practice and Regulations
in force at the time of installation.
• It has not been modified in any way, other than by Heatrae Sadia Heating.
• It has not been frost damaged.
• It has not been tampered with or been subjected to misuse or neglect.
• Within 60 days of installation the user completes and returns the certificate supplied along with the proof of purchase to register the product. Evidence of purchase and date of supply must be submitted. These guarantees do not affect your statutory rights.

Plumbing:
22mm pipework on connections on all models. Primary filling
loop and Primary drain point valve and hose connector supplied, bottom or side entry via panel knock outs.

Tundish:
Factory fitted 15mm inlet and 22mm compression outlet.

Temperature Relief Valve:
Pressure Relief valve factory set to 3 bar. Cylinder fitted with
Temperature and Pressure Relief valve, factory set to operate at 10 bar/90°C.

WaterExpansion:
Primary system expansion vessel (12 litre/3 bar) factory fitted.
Potable water expansion vessel (18 litre/3.5 bar) supplied loose.
 


Products

Boilers

Mains Pressure

Gas Fires

Electric Fires

Hot Water Cylinders

Thermal Stores

Order Form

Contact Us

Terms

www.gasapplianceguide.co.uk is operated by mdepot

 

Website management by Little House Associates

Visit Shower Right - Specialist wet room, shower pod and bathroom equipment for the able and disabled

 

Visit Mobility Depot - showers, baths and mobility equipment for the disabled