Home Up Performa 24 Performa 28 Performa 28i Powermax HE Promax 15 Promax 24 Promax System HE Kingfisher MFL Osprey 2 System Boilers Suprima L Profile L Balanced Flue Fanned Flue Baxi Platinum Combi Boilers Baxi 100 HE System Boiler Baxi Conventional Boilers Combi HE Plus Series
| |
|
Potterton
System Boilers |
Boilers from
Potterton |
|
System boilers neatly
incorporate a number of components found outside of the boiler on
traditional installations - the pump for example. Another is the expansion
vessel, which replaces the tank in the roof-space. So installation is
easier and quicker and the risk of burst pipes in winter is eliminated.
Performa System boilers are fully factory assembled with a neat, smooth
and easy to clean casing. A pre-plumbing jig with isolating valves allows
pipework to be connected and flushed prior to fitting the boiler. A choice
of concentric or twin pipe flue systems facilitates a wide choice of
location.
|
| |
Units |
Performa
System 12e |
Performa
System 18e |
Performa
System 24e |
Performa
System 28e |
| Heat Output |
kW |
12.4 |
17.5 |
24.0 |
29.4 |
| Heat Input |
kW |
13.8 |
19.4 |
26.3 |
32.6 |
| Automatic
modulation of heat output |
|
Yes |
Yes |
Yes |
Yes |
| Natural Gas |
|
Yes |
Yes |
Yes |
Yes |
| LPG
conversion kit |
|
Yes |
Yes |
Yes |
Yes |
| Case height |
mm |
780 |
780 |
780 |
780 |
| Case width |
mm |
450 |
450 |
450 |
450 |
| Case depth |
mm |
345 |
345 |
345 |
345 |
| Suitable for
unventilated compartments |
|
Yes |
Yes |
Yes |
Yes |
| Concealed
user controls |
|
Yes |
Yes |
Yes |
Yes |
| Operating
mode selector switch with reset |
|
Yes |
Yes |
Yes |
Yes |
| User
adjustable output temperature |
|
Yes |
Yes |
Yes |
Yes |
| 10 LED
temperature/status/fault display |
|
Yes |
Yes |
Yes |
Yes |
| Seasonal
Efficiency (SEDBUK) Rating |
|
78.8% |
78.7% |
78.5% |
78.2% |
| Min
installation clearance above |
mm |
200 |
200 |
200 |
200 |
| Min
installation clearance below |
mm |
200 |
200 |
200 |
200 |
| Min
installation clearance left |
mm |
5 |
5 |
5 |
5 |
| Min
installation clearance right |
mm |
5 |
5 |
5 |
5 |
| Min
installation clearance front operating |
mm |
5 |
5 |
5 |
5 |
| Min
installation clearance front servicing |
mm |
450 |
450 |
450 |
450 |
| Max gas rate |
m3/h |
2.78 |
3.45 |
2.78 |
3.45 |
| Inlet supply
pressure Natural Gas G20 |
mbar |
20 |
20 |
20 |
20 |
| NOx Class |
|
3 |
3 |
3 |
3 |
| Max capacity
of CH system |
litres |
125 |
125 |
125 |
125 |
| Safety
discharge pressure |
bar |
3 |
3 |
3 |
3 |
| Automatic
bypass |
|
Yes |
Yes |
Yes |
Yes |
| Pre-plumbing
wall plate |
|
Yes |
Yes |
Yes |
Yes |
| Gas copper
tail |
mm |
22 |
22 |
22 |
22 |
| Flow and
return copper tails |
mm |
22 |
22 |
22 |
22 |
| Pressure
relief discharge copper tail |
mm |
15 |
15 |
15 |
15 |
| Installation
lift weight |
kg |
37 |
39 |
37 |
39 |
| Electrical
supply |
V/Hz |
230/50 |
230/50 |
230/50 |
230/50 |
| Power
consumption |
W |
170 |
190 |
170 |
190 |
| Electrical
protection |
|
IPX5D |
IPX5D |
IPX5D |
IPX5D |
| Soft
electronic ignition |
|
Yes |
Yes |
Yes |
Yes |
| CH frost
protection |
|
Yes |
Yes |
Yes |
Yes |
| 24-hour pump
exercise |
|
Yes |
Yes |
Yes |
Yes |
| Standard
concentric flue length |
m |
1 |
1 |
1 |
1 |
| Max
concentric horizontal flue length (equivalent) |
m |
5 |
4 |
5 |
4 |
| Concentric
horizontal flue terminal diameter |
mm |
100 |
100 |
100 |
100 |
| Max
concentric vertical flue length (equivalent) |
m |
4 |
4 |
4 |
4 |
| Max
twin-tube vertical flue length (total equivalent) |
m |
15 |
12 |
15 |
12 |
| Price |
|
£441.85 |
£513.29 |
£548.31 |
£700.82 |
|