The Ultimate fanned
flue wall hung cast iron boiler is renowned for its quality and
reliability, and is truly regarded as the "Go Anywhere... Do
Anything" boiler.
Available in a wide
range of outputs to closely match your central heating and hot water
requirements the fanned flue Ultimate is suitable for all types of
property and system, new or old.
The Ultimate is quiet
and efficient too, being rated SEDBUK ‘D’ as required by the very
latest building regulations. The stylish stove white finish with grey trim
will complement any kitchen setting.
30FF
40FF
50FF
60FF
70FF
80FF
100FF
120FF
Water content
2.35L
2.35L
2.35L
2.95L
3.35L
3.35L
3.8L
3.8L
Total weight
inc. flue
43.4kg
43.4kg
43.4kg
47.5kg
51kg
51kg
71kg
71kg
Max static
head
27m
27m
27m
27m
27m
27m
27m
27m
Min static
head
1m
1m
1m
1m
1m
1m
1m
1m
Max output
8.79kW
11.72kW
14.65kW
17.58kW
20.52kW
23.45kW
29.31kW
35.17kW
Min output
5.86kW
8.79kW
11.72kW
14.65kW
17.85kW
20.52kW
23.45kW
29.31kW
SEDBUK rating
79.9%
78.7%
78.8%
79.4%
79.3%
79.4%
79.5%
78.1%
Price
being updated please call
being updated please call
being updated please call
being updated please call
being updated please call
being updated please call
being updated please call
being updated please call
STD Flue
Product
Specification
30-60
70-80
50
LPG
80
LPG
100-120
GAS TYPE
G20
natural gas
G31
LPG kit
SYSTEM
Gravity
DHW pumped CH
Fully
pumped open vented
Sealed system
Optional
Sealed system
kit
FLUEING
OPTIONS
Horizontal
(top flue) with bends
Horizontal
top flue
Vertical/Vertical
with bends
Horizontal
with Bends
Horizontal
USER
CONTROLS
Fully
automatic
Central
heating temperature control
Notes
•
The boiler
must be installed by a competent person in accordance with the rules in
force in the United Kingdom.
•
The
Ultimate 30-120FF and FF/LPG models do not require a system bypass if used
on a 3-port ("Y" plan or flowshare) valve system, where one port
(to domestic hot water heating or central heating) is always open.
However, on systems controlled with 2 port valves ("S" plan)
then a system bypass should be provided. If required, minimum bypass
should be: 15mm - 30FF to 60FF. 22mm - 70FF to 80FF. 28mm 100FF to 120FF.
•
A combined cold
feed and vent system as described in the latest copy of BS5449 can be used
with Ultimate 30-80FF and FF/LPG models provided that the minimum static
head is 1.5 metres or above.
• Where
TRV’s are used one radiator should be left uncontrolled or a separate
system bypass must be fitted. It is acceptable to use one radiator as a
bypass if fitted with two lockshield valves.
•
The
domestic hot water cylinder must be a double feed (fully indirect) design.