Home Up Turbomaxpro Selecting your Vaillant Boiler Vaillant TurboMax Vaillant TurboMax Pro Vaillaint EcoSystem Boilers Vaillant EcoMax Vaillant EcoMax Pro Vaillant THERMOcompact Vaillant Flues and Accessories Vaillant ecoTEC plus combi Vaillant ecoTEC pro combi Vaillant ecoMAX combi Vaillant ecoTEC plus system Vaillant ecoMAX system Vaillant ecoMAX pro open vent Vaillant uniSTOR cylinder Vaillant auroSTOR Solar Cylinders Vaillant auroTHERM Solar Packs Vaillant Solar F.A.Q
| |
|
Vaillant
TurboMax Combi Boiler |

|
The compact dimensions
and styling of the TURBOmax Plus have been designed to blend in with any
kitchen. The rear flue outlet option also means no elbow is visible above
the boiler.
With minimal side clearances and no compartment ventilation required, it
is also ideal for installation in cupboards or compartments |

|
|
|
 |
Installation
could not be simpler with clip distance pipework connections
and a built-in filling loop. A choice of horizontal, vertical
and a rear flue option, along with a number of telescopic
accessories, also provides total siting flexibility. |
|
'AquaComfort' system provides superb
hot water performance. This system incorporates both a warmstart facility
to provide instantaneous hot water delivery and a special flow sensor
which ensures constant hot water temperatures over a wide operating range.
The boiler is also suitable for areas with low water pressure, providing
full flow rate at just 0.5 bar.
|
 |
Built-in
boiler display system shows status and diagnostic information
for easy commissioning and subsequent service work. |
|
The drop-down control box allows
easy access to components for service work. The single electronic circuit
board incorporates a built-in 2 stage frost thermostat to protect the
boiler in freezing conditions. Designed with reliability in mind, the
TURBOmax Plus comes with the added reassurance of a full 2 year guarantee
|
|
Please
Note: Due to constant changes in the Boiler market, the following prices
may be incorrect. We try our best to keep up with the changes but please
check before ordering to avoid future complications and disappointments. |
|
Technical
specification chart
|
-
|
TURBOmax
Plus 824EH
|
TURBOmax
Plus 828EH
|
TURBOmax
Plus 837E
|
|
PRICE INCLUDING VAT
(Excluding flue and timer)
|
£675.81
|
£718.68
|
£887.45
|
|
Flue type
|
-
|
RSF
|
RSF
|
RSF
|
|
Maximum DHW heat output
|
kW
|
24.0
|
28.0
|
36.9
|
|
Maximum DHW heat input (net)
|
kW
|
26.7
|
31.1
|
31.1
|
|
DHW flow rate @ 35oC
temperature rise
|
L/min
|
9.8
|
11.5
|
15.1
|
|
Mains water pressure required for
max. flow rate
|
Bar
|
0.5
|
0.5
|
0.5
|
|
CH heat output range (80oC
flow/60oC return)
|
kW
|
8.9-24.0
|
10.4-28.0
|
10.9-28.0
|
|
CH heat output range (50oC
flow/30oC return)
|
kW
|
-
|
-
|
-
|
|
Maximum CH heat input (net)
|
kW
|
26.7
|
31.1
|
31.1
|
|
Connections heating flow/return
|
mm
|
22*
|
22*
|
22*
|
|
Cold water inlet
|
mm
|
15*
|
15*
|
15**
|
|
DHW outlet
|
mm
|
15*
|
15*
|
15**
|
|
Gas inlet
|
mm
|
15*
|
15*
|
22*
|
|
Pressure relief discharge pipework
|
mm
|
15**
|
15**
|
15*
|
|
Condensate drain (internal diameter
min.)
|
mm
|
-
|
-
|
-
|
|
Electrical connection
|
V/Hz
|
230/50
|
230/50
|
230/50
|
|
Power input
|
W
|
150
|
150
|
-
|
|
Dimensions external case height
(excl. flue)
|
mm
|
800
|
800
|
800
|
|
Overall height (incl. standard flue
elbow)
|
mm
|
968
|
968
|
968
|
|
External case width
|
mm
|
440
|
440
|
440
|
|
External case depth
|
mm
|
338
|
338
|
338
|
|
Weight approx.
|
kg
|
43
|
45
|
48
|
|
LPG model available
|
-
|
Yes
|
Yes
|
Yes
|
*Copper tail pipe clip distance from