Home Up Powermax HE Promax 15 Promax 24 Promax System HE Balanced Flue Fanned Flue Baxi Platinum Combi Boilers Baxi 100 HE System Boiler Baxi Conventional Boilers Combi HE Plus Series
| |
|
|
|
The Potterton
Powermax HE combines a condensing stainless steel heat engine, unvented
Duplex stainless steel domestic hot water cylinder, pump and programmer in
a single package - virtually 'a system in a box'. Installation is reduced
to just seven pipework connections plus the flue, which is available in a
wide range of options for freedom of siting the boiler and the flue
terminal. |
|
High performance
central heating and hot water in one box. For a complete installation just
add the flue kit, radiators, valves and pipework. |
|
|
|

|

|
- Three models to suit the
majority of situations, serving up to 2 bathrooms, an en-suite, a
cloakroom and a kitchen
- DHW flowrates up to 48
l/min - filling a bath in around 5 minutes
- Operates at water
pressures as low as 1.0 bar
- Rapid recovery of store
(15-20 mins)
- Output modulating down
to 6.7 kW for maximum efficiencyv
- Automatic by-pass for
systems with thermostatic radiator valves
- Integrated and pre-wired
7 day 3 period electronic programmer with battery back up
- On-board diagnostic
functions with LED display
- Built-in frost
protection
- User selectable hot
water store temperature
- Boiler heat exchanger
and storage cylinder in high quality stainless steel
- Cylinder guaranteed 10
years
- Optional back-up
electric immersion heater
- Comprehensive concentric
and twin pipe flue options
|
| |
85 litre |
115 litre |
150 litre |
| Price |
£ |
£ |
£ |
Price List being updated. Sorry
for the inconvenience. Please call
| Powermax |
Units |
85
litre |
115
litre |
150
litre |
| Max Heat
Input |
kW |
25.8 |
25.8 |
25.8 |
| Max Output
to CH (non condensing)
| kW |
22.6 |
22.6 |
22.6 |
| Max Output
to CH (condensing) |
kW |
24.0 |
24.0 |
24.0 |
| Min Output
to CH (non condensing)
| kW |
6.7 |
6.7 |
6.7 |
| Min Output
to CH (condensing)
| kW |
7.6 |
7.6 |
7.6 |
| Automatic
modulating of CH heat output |
Yes |
Yes |
Yes |
| Case height |
mm |
1110 |
1270 |
1460 |
| Case width |
mm |
550 |
550 |
550 |
| Case depth |
mm |
600 |
600 |
600 |
| Built
in programmer |
2-channel,
pre=programmed, back lit display, battery back-up, separate times for HW
& CH, advance button, CH off selector |
| User
adjustable DHW temperature |
Yes |
Yes |
Yes |
| LED
status/fault display |
Yes |
Yes |
Yes |
| Seasonal
Efficiency (SEDBUK) Rating |
%/Class |
90.5/A |
90.5/A |
90.6/A |
| Suitable
for unventilated compartments |
No |
No |
No |
| Min
effective high and low ventilation to room |
cm2 |
80 |
80 |
80 |
| Min
effective high and low ventilation to outside |
cm2 |
40 |
40 |
40 |
| Min
installation clearance above |
mm |
250 |
250 |
250 |
| Min
installation clearance front |
mm |
75 |
75 |
75 |
| NOx
class |
5 |
5 |
5 |
| Max gas rate |
m3/h |
2.55 |
2.55 |
2.55 |
| Inlet
pressure |
mbar |
20 |
20 |
20 |
| Fuel |
Natural
Gas |
| Secondary
store capacity |
litres |
85 |
115 |
150 |
| Secondary
expansion vessel |
18
litre, pre-charge 2.5 - 2.7 bar (supplied separately) |
| Automatic
bypass |
Yes |
Yes |
Yes |
| DHW
temperature |
°C |
45 to 65 |
45 to 65 |
45 to 65 |
| DHW flowrate
2 |
l/min |
30 |
36 |
48 |
| Working
pressure - Primary |
bar |
09 - 2.5 |
0.9 - 2.5 |
0.9 - 2.5 |
| Working
pressure - DHW |
bar |
1.0 - 2.5 |
1.0 - 2.5 |
1.0 - 2.5 |
| Working
pressure - Mains supply |
bar |
1.0 - 16.0 |
1.0 - 16.0 |
1.0 - 16.0 |
| Pressure
relief valve setting |
bar |
3.0 |
3.0 |
3.0 |
| Temperature/press.
Relief Valve |
Pre-set
95°C, 10.0 bar opening |
| Lift weight
top section |
kg |
40 |
40 |
40 |
| Lift weight
bottom section |
kg |
40 |
41 |
43 |
| Full weight |
kg |
175 |
208 |
246 |
| Gas |
mm |
22-
compression |
| CH flow
& return |
mm |
22-
compression |
| DHW inlet
& outlet |
mm |
22-
tube end |
| TPRV |
mm |
22-
compression from tundish |
| Condensate
outlet |
Flexible
pipe 500mm long, (fits 21.5mm PP overflow systems) |
| Inlet
control group |
mbar |
22mm
compression inlet & outlet set pressure 2.5 bar, PRV set 8.0 bar |
| Electric
supply |
V-Hz |
230-50 |
230-50 |
230-50 |
| Power
consumption |
W |
96 |
96 |
96 |
| Noise level |
dBA |
48 |
48 |
48 |
| Optional
immersion heater |
3
kW at 240V, BEAB approved |
| CH
frost protection |
Yes |
Yes |
Yes |
| Concentric
flue size |
mm |
100 |
100 |
100 |
| Twin pipe
flue size |
mm |
60 |
60 |
60 |
|